B) ** BER (BIT
ERROR RATE) TEST METHOD:
1. The device under test (DUT) can be either a Primary or a
Secondary Station. But during the test, the DUT always
plays the Secondary role.
2. The DUT will use its native IrDA hardware and native IrDA
driver stack which implemented the Test Frame in IrLAP as
specified in the IrDA Protocol Spec. No special test software
is necessary during the test at the DUT side.
3. The Tester (Test Reference station) is a PC with IrDA
hardware of controlled IR emission intensity (e.g. ACTiSYS
IR2000B/L or IR3200M) and a special test software (e.g.
ACTiSYS
ACT-IR9003SW), but not stack testing. The Tester always play
the
Primary role.
|